Brand Name : HAIYING
Model Number : BSC-1000A2
Certification : CE
Place of Origin : CHINA
MOQ : 1 set
Price : Negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Packaging Details : Wooden case
Type : Blood Testing Equipments
Overall size : 1200×800×2120mm
Purification area size : 1000×700×600mm
Product name : Biosafety cabinet
Model : BSC-1000A2
Downflow velocity : 0.31±0.025m/s
Inflow velocity : 0.48±0.025m/s
Features : Electric front window
Model | BSC-1000A2 |
Clean Grade | HEPA:ISO 5 calss ( Class100 ) |
ULPA:ISO 4 Class ( Class10 ) | |
HEPA Filter | HEPA:≥99.995% , @0.3μm |
ULPA:≥99.999% , @0.12μm | |
Air tightness | 99.99≤E≤99.999 |
Overall Dimensions | 1200×800×2120mm |
Working Space | 1000×700×600mm |
Downflow Velocity | 0.35m/s |
Forward intake wind speed | 0.25m/s±0.025m/s |
Classification of BSC Biosafety Cabinet:
According to the NSF49 standard, the medium of biosafety level 1 (P1) refers to ordinary harmless bacteria, viruses and other microorganisms; the medium of biosafety level 2 (P2) refers to general pathogenic bacteria, viruses and other microorganisms; biosafety The medium of level 3 (P3) refers to microorganisms such as potent/fatal bacteria and viruses, but can be cured after infection; the medium of biosafety level 4 (P4) refers to microorganisms such as potent/fatal bacteria, viruses, etc., and it is not easy to cure after infection . This standard divides biological safety cabinets into levels I, II, and III, which can be applied to the operation of media with different levels of biological safety.
Principles for choosing BSC Biosafety Cabinet in biosafety laboratories:
When the laboratory level is level 1, there is generally no need to use a biological safety cabinet or a level I biological safety cabinet. When the laboratory level is level two, when microbial aerosols or spills may occur, a level I biological safety cabinet can be used; when handling infectious materials, a level II biological safety cabinet with partial or full ventilation should be used ; If it involves handling chemical carcinogens, radioactive substances and volatile solvents, only Class II-B full exhaust (B2 type) biological safety cabinets can be used. When the laboratory level is level three, a level II or level III biological safety cabinet should be used; all operations involving infectious materials should use a fully exhausted type II-B level (B2 type) or level III biological safety cabinet. When the laboratory level is level four, a level III full exhaust biological safety cabinet should be used. When personnel wear positive pressure protective clothing, a Class II-B biological safety cabinet can be used.
![]() |